B-58 StorageWorks Fibre Channel Storage Switch User's Guide
Compaq Confidential – Need to Know Required
Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:
Part Number: AA-RHBYA-TE 135267-001 File Name: i-appb Telnet Commands Last Saved On: 4/7/99 12:36 PM
Table B-12
switchShow Command Field Descriptions
continued
Field
Description
GBIC type
The GBIC type follows the port number. The four GBIC types
include:
-- no GBIC present
sw shortwave GBIC
lw longwave GBIC
cu copper GBIC
Port state
The port state follows the GBIC type. The possible port states
include:
No_Card no card present in this Switch slot
No_Module no GBIC module in this port
No_Light the module is not receiving light
No_Sync the module is receiving light but is out of sync
In_Sync the module is receiving light and is in sync
Laser_Flt the module is signaling a laser fault (defective GBIC)
Port_Flt the port has been marked faulty (defective GBIC,
cable, or device)
Diag_Flt the port failed diagnostics (defective G_Port or
FL_Port card or motherboard)
Online the port is up and running
Lock_Ref the port locking to the reference signal
Comment field
The comment field follows the port state. The possible
comments include:
Disabled the port is disabled
Loopback the port is in loopback mode
E_Port the WWN and Switch name of the other Switch is
shown, the use of this ISL is shown (see FC_SW)
F_Port the WWN of the N_Port is shown
G_Port the port is online but is not yet an E_Port or F_Port
L_Port the port is connected to an arbitrated loop