Vec: vector & accuracy data, Function, Command format – Spectra Precision ProMark 800 Reference Manual User Manual
Page 394: Response format

382
Query Command Library
VEC: Vector & Accuracy Data
Function
This command is used to query the receiver for vector and
accuracy data.
Command Format
Syntax
$PASHQ,VEC[*cc]
Response Format
Syntax
$PASHR,VEC,c1,d2,m3,f4,f5,f6,f7,f8,f9,f10,f11,f12,d13*cc
Parameters
Example
$PASHQ,VEC
$PASHR,VEC,3,09,130924.00,-37.683,55.081,-17.925,0.016,0.012,0.026,
0.234765,0.098765,0.098763,0001*71
Parameter
Description
Range
c1
Position mode:
• 0: Autonomous
• 1: RTCM (or SBAS Differential)
• 2: RTK float
• 3: RTK fixed
• 9: SBAS Differential. See comment.
0-3, 9
d2
Number of SVs used in position compu-
tation
3-27
m3
UTC time (hhmmss.ss)
000000.00-235959.99
f4
X component of vector (along ECEF X
axis), in meters
±99999.999
f5
Y component of vector (along ECEF Y
axis), in meters
±99999.999
f6
Z component of vector (along ECEF Z
axis), in meters
±9999.999
f7
X component standard deviation
99.999
f8
Y component standard deviation
99.999
f9
Z component standard deviation
99.999
f10
XY correlation
±9.999999
f11
XZ correlation
±9.999999
f12
YZ correlation
±9.999999
d13
Base station ID (RTCM only)
0-4095
*cc
Checksum
*00-*FF