beautypg.com

Atm: atom data parameters, Function, Command format – Spectra Precision ProMark 800 Reference Manual User Manual

Page 279: Response format

background image

267

Query Command Library

ATM: ATOM Data Parameters

Function

This command allows you to read the current settings of the
ATOM data-related parameters.

Command Format

Syntax

$PASHQ,ATM[*cc]

Response format

Syntax

(Through an example)

$PASHQ,ATM

PER:001.00 ELM:5
DRI:001.00 SIT:2007 REC:N MEM:M
ANH:02.132 ANT:VERT ANR:ON
ATOM: MES PVT ATR NAV DAT EVT BAUD
PRTA: OFF OFF OFF OFF OFF OFF 7
PRTC: OFF OFF OFF OFF OFF OFF 1
PRTE: OFF OFF OFF OFF OFF OFF 1
MEMM: OFF OFF OFF OFF OFF OFF 1
MEMU: OFF OFF OFF OFF OFF OFF 0

Parameters

Parameter

Description

Range

PER

ATOM output rate

0.00-999.0 s

ELM

Elevation mask used in data recording &
data output

0-90

DRI

Recording rate

0.00-999.0 s

SIT

Site ID

4 characters

REC

Data recording:
• Y: Data recording enabled
• N: Data recording disabled
• S: Data recording enabled but stopped

Y, N, S

MEM

Selected memory:
• M: Internal memory
• U: USB memory

M, U

ANH

Antenna height

0.000-99.999

ANT

Height measurement type (slant/vertical)

SLANT, VERT

ANR

Antenna reduction mode

ON, OFF, ARP

PRTA

ON, OFF

PRTC

Label for Bluetooth

ON, OFF

PRTE

Label for Modem

ON, OFF

MEMM
MEMU

Labels for memories

ON, OFF