Atm: atom data parameters, Function, Command format – Spectra Precision ProMark 800 Reference Manual User Manual
Page 279: Response format

267
Query Command Library
ATM: ATOM Data Parameters
Function
This command allows you to read the current settings of the
ATOM data-related parameters.
Command Format
Syntax
$PASHQ,ATM[*cc]
Response format
Syntax
(Through an example)
$PASHQ,ATM
PER:001.00 ELM:5
DRI:001.00 SIT:2007 REC:N MEM:M
ANH:02.132 ANT:VERT ANR:ON
ATOM: MES PVT ATR NAV DAT EVT BAUD
PRTA: OFF OFF OFF OFF OFF OFF 7
PRTC: OFF OFF OFF OFF OFF OFF 1
PRTE: OFF OFF OFF OFF OFF OFF 1
MEMM: OFF OFF OFF OFF OFF OFF 1
MEMU: OFF OFF OFF OFF OFF OFF 0
Parameters
Parameter
Description
Range
PER
ATOM output rate
0.00-999.0 s
ELM
Elevation mask used in data recording &
data output
0-90
DRI
Recording rate
0.00-999.0 s
SIT
Site ID
4 characters
REC
Data recording:
• Y: Data recording enabled
• N: Data recording disabled
• S: Data recording enabled but stopped
Y, N, S
MEM
Selected memory:
• M: Internal memory
• U: USB memory
M, U
ANH
Antenna height
0.000-99.999
ANT
Height measurement type (slant/vertical)
SLANT, VERT
ANR
Antenna reduction mode
ON, OFF, ARP
PRTA
ON, OFF
PRTC
Label for Bluetooth
ON, OFF
PRTE
Label for Modem
ON, OFF
MEMM
MEMU
Labels for memories