Qzs: qzss tracking status, Relevant set command, Function – Spectra Precision ProMark 800 Reference Manual User Manual
Page 355: Command format

343
Query Command Library
Parameters
Comments
With no internal battery in, fields f4, d5 and d7 are all empty.
With no external power source applied, field f6 is empty.
Example
$PASHQ,PWR
$PASHR,PWR,6.8,9.1,2,,,11.6,,44*0D
Relevant Set
Command
$PASHS,PWR,PAR
QZS: QZSS Tracking Status
Function
This command is used to read the current status of QZSS
tracking.
Command Format
Syntax
$PASHQ,QZS[*cc]
Parameters
None.
Parameter
Description
Range
f1
Battery voltage threshold, in volts, triggering a low-bat-
tery alarm
6.7-8.4
f2
External power voltage threshold, in volts, triggering a
low-power alarm
9.0-28
d3
Power source:
• 0: Internal battery
• 1: External battery
• 2: External DC source
0-2
f4
Battery DC output voltage, in volts
0.0-12.0
d5
Percentage of remaining battery energy
0-100
f6
DC input voltage from external power, in volts
0.0-30.0
d7
Battery charging status:
• 0: Charging
• 1: Discharging
• 2: Fully charged
0-2
d8
Internal temperature, in °Celsius
*cc
Checksum
*00-*FF