beautypg.com

Code domain – Agilent Technologies N9010A User Manual

Page 293

background image

Chapter 33

293

W-CDMA Measurement Application

Measurements

Description

Specifications

Supplemental Information

Code Domain

(BTS Measurements

RF input power and attenuation are set
to meet the Mixer Level range.

−25 dBm ≤ ML

a

≤ −15 dBm

20 to 30°C)

Code domain power

Absolute accuracy

b

±0.29 dB (95th percentile)

(

−10 dBc CPICH, Atten = 10 dB)

Relative accuracy

Code domain power range

0 to

−10 dBc

±0.015 dB

−10 to −30 dBc

±0.06 dB

−30 to −40 dBc

±0.07 dB

Power Control Steps

Accuracy

0 to

−10 dBc

±0.03 dB

−10 to −30 dBc

±0.12 dB

Power Dynamic Range

Accuracy

±0.14 dB

(0 to

−40 dBc)

Symbol power vs. time

Relative accuracy

Code domain power range

0 to

−10 dBc

±0.015 dB

−10 to −30 dBc

±0.06 dB

−30 to −40 dBc

±0.07 dB

Symbol error vector magnitude

Accuracy

±1.0% (nominal)

(0 to

−25 dBc)

a. ML (mixer level) is RF input power minus attenuation.
b. Code Domain Power Absolute accuracy is calculated as sum of 95% Confidence Absolute Amplitude

Accuracy and Code Domain relative accuracy at Code Power level.