Edr carrier frequency stability – Agilent Technologies N9010A User Manual
Page 202
202
Chapter 21
Bluetooth Measurement Application
Enhanced Data Rate (EDR) Measurements
Description
Specifications
Supplemental Information
EDR Carrier Frequency
Stability
This measurement is a Transmit
Analysis measurement and is in
conformance with Bluetooth RF
test specification 2.1.E.0.5.1.13
Packet Type
2-DH1, 2-DH3, 2-DH5, 3-DH1,
3-DH3, 3-DH5
Payload
PRBS9, BS00, BSFF, BS55
Synchronization
DPSK synchronization sequence
Trigger
External, RF Burst, Periodic
Timer, Free Run, Video
Supported measurements
Worst case initial frequency
error(
ω
i
) for all packets (carrier
frequency stability), worst case
frequency error for all blocks
(
ω
o
), (
ω
o
+
ω
i
) for all blocks
RF input level range
a
+30 dBm to –70 dBm
Carrier Frequency Stability and
Frequency Error
b
±100 Hz + tfa
c
(nominal)
a. When the input signal level is lower than –40 dBm, the analyzer’s preamp should be turned on and the
attenuator set to 0 dB.
b. Example, using 1 ppm as frequency reference accuracy of the analyzer, at frequency of 2.402 GHz,
frequency accuracy would be in the range of ±(2.402 GHz
× 1 ppm) Hz ± 100 Hz = ±2402 Hz ± 100 Hz
= ±2502 Hz.
c. tfa = transmitter frequency × frequency reference accuracy.