beautypg.com

Modulation analysis settings – Agilent Technologies N9010A User Manual

Page 219

background image

Chapter 23

219

CMMB Measurement Application

Measurements

Description

Specifications

Supplemental Information

Modulation Analysis Settings

Device Type

Transmitter or Exciter

Trigger

FreeRun, External 1, External 2
or Periodic Timer

External Trigger is used with 1
PPS input from GPS, (this
trigger method is recommended
for SFN mode)

Periodic Timer Trigger is used
usually used for MFN mode or
SFN mode without 1 PPS input

FreeRun can be used when all
of the timeslots use the same
Mod Format (this trigger mode
is recommended for Exciter
under Test Mode)

Sync Frame Now

Immediate Action to synchronize
CMMB signals when using
Periodic Timer or External Trigger

Meas Type

PLCH, Timeslot or Frame

PLCH Settings

CLCH or SLCH (0-38)

Enabled when Meas Type is PLCH

Timeslot Settings

Start Timeslot

Meas Interval

Modulation Format: BPSK,
QPSK or 16 QAM

Enabled when Meas Type is
Timeslot

MER Limit

38 dB as default

Auto or Manual

Spectrum

Normal or Invert

Clock Rate

10.0 MHz

Auto or Manual

Demod Symbols Per Slot

4 to 53

Out of Band Filtering

On or Off

Data Equalization

On or Off