beautypg.com

1 db gain compression point – Agilent Technologies N9010A User Manual

Page 142

background image

142

Chapter 13

Option P03, P07, P13, P26, P32 and P44 - Preamplifier

Other Preamp Specifications

Description

Specifications

Supplemental Information

1 dB Gain Compression Point

(Two-tone)

a

(Preamp On (Option P03, P07, P13, P26, P32,
P44)

Maximum power at the preamp

b

for 1 dB gain

compression)

10 MHz to 3.6 GHz

−14 dBm (nominal)

3.6 to 26.5 GHz

Tone spacing 100 kHz to 20 MHz

−28 dBm (nominal)

Tone spacing > 70 MHz

–20 dBm (nominal)

>26.5 GHz

–30 dBm (nominal)

a. Large signals, even at frequencies not shown on the screen, can cause the analyzer to mismeasure

on-screen signals because of two-tone gain compression. This specification tells how large an interfer-
ing signal must be in order to cause a 1 dB change in an on-screen signal.

b. Total power at the preamp (dBm) = total power at the input (dBm)

− input attenuation (dB).