Initial carrier frequency tolerance – Agilent Technologies N9010A User Manual
Page 198
198
Chapter 21
Bluetooth Measurement Application
Low Energy Measurements
Description
Specifications
Supplemental Information
Initial Carrier Frequency
Tolerance
This measurement is a Transmit
Analysis measurement and is in
conformance with Bluetooth RF
test specification
LE.RF-PHY.TS/0.7d2.6.2.4.
Packet Type
Reference type
Payload
PRBS9, BS00, BSFF, BS0F,
BS55
Synchronization
Preamble
Trigger
External, RF Burst, Periodic
Timer, Free Run, Video
RF input level range
a
+30 dBm to –70 dBm
Measurement range
Nominal channel freq ± 100 kHz
(nominal)
Measurement Accuracy
b
±100 Hz + tfa
c
(nominal)
a. When the input signal level is lower than –40 dBm, the analyzer’s preamp should be turned on and the
attenuator set to 0 dB.
b. Example, using 1 ppm as frequency reference accuracy of the analyzer, at frequency of 2.402 GHz,
frequency accuracy would be in the range of ±(2.402 GHz
× 1 ppm) Hz ± 100 Hz = ±2402 Hz ± 100 Hz
= ±2502 Hz.