beautypg.com

Modulation accuracy (composite rho) – Agilent Technologies N9010A User Manual

Page 211

background image

Chapter 22

211

cdma2000 Measurement Application

Measurements

Description

Specifications

Supplemental Information

Modulation Accuracy (Composite
Rho)

Set the attenuation to meet the Mixer
Level requirement. Specifications
apply to BTS for 9 active channels as
defined in 3GPP2

(BTS Measurements

−25 dBm ≤ ML

a

≤ −15 dBm

20 to 30

°C)

RF input power and attenuation are set
to meet the Mixer Level range

Composite EVM

Range


0 to 25

%

Floor

1.6

%

Accuracy

b

±1.0%

±0.5%


At EVM measurement in the range of
12.5% to 22.5%

Composite Rho

Range


0.94118 to 1.0

Floor

0.99974

Accuracy

±0.0010

±0.0030

at Rho 0.99751 (EVM 5

%)

at Rho 0.94118 (EVM 25

%)

Pilot time offset

Range

−13.33 to +13.33 ms


From even second signal to start of PN
sequence

Accuracy

±300 ns

Resolution

10 ns

Code domain timing

Range

±200 ns

Pilot to code channel time tolerance

Accuracy

±1.25 ns

Resolution

0.1 ns

Code domain phase

Range

±200 mrad

Pilot to code channel phase tolerance

Accuracy

±10 mrad

Resolution

0.1 mrad

Peak code domain error

Accuracy

±1.0 dB (nominal)
Range from

−10 dB to −55 dB

I/Q origin offset

DUT Maximum Offset

Analyzer Noise Floor

−10 dBc (nominal)

−50 dBc (nominal)

Frequency error

Range

±900 Hz

Accuracy

±10 Hz + tfa

c