145

Option P03, P07, P13, P26, P32 and P44 - Preamplifier

Other Preamp Specifications

Description

Specifications Supplemental Information

RF Input VSWR

DC coupled, 0 dB atten

(at tuned frequency, Freq Option

≤ 526)

95th Percentile

a

Band 0 (0.01 to 3.6 GHz)

1.52

Band 1 (3.5 to 8.4 GHz)

1.68

Band 2 (8.3 to 13.6 GHz)

1.69

Band 3 (13.5 to 17.1 GHz)

1.66

Band 4 (17.0 to 26.5 GHz)

1.66

Nominal VSWR vs. Freq.

See plots following

a.

X-Series analyzers have a reflection coefficient that is excellently modeled with a Rayleigh
probability distribution. Agilent recommends using the methods outlined in Application Note
1449-3 and companion Average Power Sensor Measurement Uncertainty Calculator to com-
pute mismatch uncertainty. Use this 95th percentile VSWR information and the Rayleigh
model (Case C or E in the application note) with that process.