Teledyne LeCroy Sierra M122 User Manual User Manual
Page 344

Teledyne LeCroy
Sierra Trainer Generation Language
342
Sierra M122 SAS/SATA Protocol Analyzer User Manual
SAS Speed Negotiation Settings
OOB_SAS_Align1_Time
81920
ALIGN(1) time for SAS speed negotiation in
OOBIs.During the specified period, the generator will
transmit ALIGN(1) primitives.
OOB_SAS_Align0_Time
81920
ALIGN(0) time for SAS speed negotiation in
OOBIs.During the specified period, the generator will
transmit ALIGN(0) primitives.
OOB_SAS_Interspeed_Time 750000
Interspeed time for SAS speed negotiation in
OOBIs.During the specified period, the generator will
keep the line at electric idle.
OOB_SpeedNeg_MTT.
29998080
OOBI
The maximum time in OOBI during which training
phase of speed negotiation should be completed in
Train‐SNW.
OOB_SpeedNeg_SNTT.
2200
OOBI
The time in OOBI during which generator transmits
phy capability bits in SNW‐3. In Automatic
connection This value is also used for the time during
which generator sends Align0 and Align1 in SNW1
and SNW2.
OOB_SpeedNeg_BCT.
2200
OOBI
The time in OOBI during which generator transmits
COMWAKE or D.C. idle during SNW‐3.
OOB_SpeedNeg_MTTT
750000000
OOBI
The maximum time for transmitter training to
complete during Train_Tx‐SNW.
OOB_SpeedNeg_COEF_Sett
ing.
Normal
The initial coefficient setting values to be transmitted
in the Tx‐training TTIU. The value can be one of these
values :Normal, Reference‐1, Reference‐2, No‐
equalization.
Setting
Default
Value
Description