Creating Global Rules

248

 

 

Sierra M122 SAS/SATA Protocol Analyzer User Manual

6. Click Direction to choose the direction of traffic to monitor for the selected event 

(the default is From Initiator, which is what you want for this example). 

7. Still in the middle column of the Event Properties dialog box, click Primitive to 

display a drop‐down menu that lets you choose the type of primitive for which you 
want to wait in this scenario. In this example, it is RRDY (Normal).

Figure 4.21: Example 1: Event Drop-Down List

8. Click OK to close the Event Properties dialog box.