beautypg.com

Ata command report – Teledyne LeCroy Sierra M122 User Manual User Manual

Page 132

background image

Teledyne LeCroy

Analysis

130

 

 

Sierra M122 SAS/SATA Protocol Analyzer User Manual

ATA Command Report

To display the ATA Command Report, click the ATA Command tab. The ATA Command 
Report displays information in the following columns:

Command: All, Custom, Check Power Mode, Execute Device Diagnostic, 
Flush Cache, Identify Device, Read DMA Ext, Read FPDMA Queue, Set Feature, 
Write DMA Ext, Write FPDMA Queue

PM Port

Direction: All, H‐>D, D‐>H, I‐>T, T‐>I, or Custom

Number of FIS: All, Custom, or a number

Payload Size: All, Custom, or a number of DWORDs

Status: All, Custom, Incomplete, Normal Output

Timeout: such as All, Custom, N/A, Yes, No (see 

“Time out of ATA Command 

Report” on page 130

)

Duration: All, Custom, or time unit

Count: All, Custom, or a number of occurrences

%: of total count

Figure 3.29: SATA: ATA Command Report

Time out of ATA Command Report

The Time out shows the NCQ time out. It is applicable for only NCQ commands. A 
threshold can be set in the "NCQ commands Timeout Threshold", the default value is 
1000 sec (the user can change it to any value). The statistical report provides a "Time 
out" report based on this threshold. Any NCQ command that takes more than the given 
threshold is flagged as "yes", which means that a timeout occurred for that command.