beautypg.com

1 available resources – Teledyne LeCroy Sierra M122 User Manual User Manual

Page 244

background image

Teledyne LeCroy

Scenario Actions

242

 

 

Sierra M122 SAS/SATA Protocol Analyzer User Manual

1

 Only shown in Action Properties dialog box when creating a sequence.

4.8.1

Available Resources

You can specify Events, Combined Events and Actions and additional Events. The 
application automatically checks for the maximum number of terms (Events/Actions). 
When you exceed the limit, an error is flagged, prompting you to jump to the place that 
caused the error.

The list of available resources is given below:

External Trigger X 1

Analyzer Trigger X 1

Training Detector x 4 (only M12x)

Primitive Detector (each has its own Embedded counter in M12x) X 8

Pattern Detector (each has its own Embedded counter in M12x) X 8 (a total of 12 
DWORD detectors are shared between all pattern detectors)

Frame Type Detector X 24

Counter X 12

Timer X 8

OOB X 1

ComWakeDetected X 1

ComWakeCompleted X 1

ComInitDetected X 1

ComInitCompleted X 1

ComSasDetected X 1

ComSasCompleted X 1

Snw1 X 1

Snw2 X 1

Snw3 X 1

SnwFinal X 1

SNW

Speed Negotiation 
Retime

Set RCDT, SNTT, ALT/TLT, TX speed, TRAIN/
TRAIN_DONE pattern, and/or PHY Capability.

Speed Negotiation 
Violation

Set Violation Type.

Stop Scenario

Stops all scenario activity.

Substitute Data DWORD

Substitutes a data DWORD in the traffic.

with SAS Primitive

Substitutes a SAS primitive in the traffic.

with SATA Primitive

Substitutes a SATA primitive in the traffic.

Trigger Output

Sends a signal out the trigger port to the device 
downstream.
The trigger point in the Analyzer that caused the 
analyzer trigger action will not be the selected 
event, it will be the selected event with some 
offset.

Action

Description