beautypg.com

External trig in setting, Choose port speed, Ports configuration – Teledyne LeCroy Sierra M122 User Manual User Manual

Page 103

background image

    

Sierra M122 SAS/SATA Protocol Analyzer User Manual

101

SAS/SATA Software Menus and Toolbars

  Teledyne LeCroy

6G ~ 530 ns 

3G ~ 730 ns 

1.5G ~ 1020 ns

External Trig In Setting

An external Low or High input signal can cause triggering. Select the 
External Trig In Setting: High Active, Low Active, or Toggle from High to Low or Low to 
High once (3.3 V output).

Choose Port Speed

The default speed is Autospeed. You can also select the port speed from the 
drop‐down list: 1.5 Gbps, 3.0 Gbps, 6.0 Gbps or 12.0 Gbps.

Note:

If a Port ID check box has no check, the analyzer does not capture any patterns for that port. The 

system allocates trace memory for that port to its adjacent port, for example: I1, T1 <‐> I2, T2.

Ports Configuration

Click the Port Configuration button to display the Set Port Configuration dialog.

Figure 2.71: SAS: Set Port Configuration Dialog