Configure remote control source, Configure – Xantrex Technology XDC User Manual
Page 78
Operation
Power Supply Operation
76
Operating Manual for XDC Series Power Supply
Configure
Remote
Control
Source
The REMOTE CONFIG menu option lets you set up the attributes of the remote
control sources.
The following table shows how to access and work with the Remote Configuration
option.
After you have selected the remote control source you want to configure, configure
that setting using appropriate values from the following table. Select values using the
arrow keys or the numeric keypad. To save a value you have selected, press ENTER.
See Section 4, “Remote Operation” for detailed instructions on setting up remote
interfaces.
Step # Do This
You Will See
1
ERROR MSGS
2
5 times
1
1. You can also press MENU 5 times.
REMOTE CONFIG
3
RS-232 Cfg
4
or
Press repeatedly until the desired
remote control source appears.
RS-232 Cfg
Analog Cfg
GPIB Cfg
Multichnl Cfg
5
See the tables that follow to see how
to proceed.
Remote Control
Source
Prompt
Configuration Settings
RS-232
Baud ######
Flow Ctl ####
1200, 2400, 4800, 9600, 19200,
38400
1
Hdwr, XON, None
2
1. This range depends on the user’s network configuration.
2. Hdwr = hardware handshake; XON = software flow control XON/XOFF characters used; None
= no flow control
Analog
Input #### V
Select the operating range of the
API:
0–5
0–10
GPIB
GPIB Addr ##
PON SRQ? Y
1–30
Y, N
Multichannel
Slave Addr ##
Connect?
2-50
Y, N
MENU
ENTER
ENTER