beautypg.com

Output hold-up time – source interruption, Transient response time, Mode crossover – Xantrex Technology XDC User Manual

Page 243: Peak–peak and rms noise bandwidth limits, Maximum remote sense line drop compensation, Isolation

background image

Specifications and Characteristics

Output Performance Specifications

Release 3.0

241

Output Hold-Up Time – Source Interruption

Minimum 4 ms with output deviation less than 5% of maximum output voltage after
source interruption.

Transient Response Time

1

Time to recover within 0.75% of rated output of previous level after step change in
load current between 50% and 100%.

Mode Crossover

Maximum deviation as a percentage of rated output voltage.

Peak–Peak and RMS Noise Bandwidth Limits

The frequency range for Peak to Peak measurements is 10 Hz–20 MHz.
The frequency range for RMS measurements is 10 Hz–100 kHz.

Maximum Remote Sense Line Drop Compensation

Minimum 3.8 V for each line, 5 V typical

Isolation

1. Time for the output voltage to recover within 0.75% of rated output of its previous level

after a step change in load current of up to 50% - 100% and 100% to 50% of rated

output

Mode

Time

Voltage Mode

3 ms (6000 W models)

Voltage Mode

35 ms (12000 W models)

CV – CC Overshoot

1%

AC Input to Output

1350 V

ac

AC Input to Chassis

1350 V

ac

Output to Chassis

600 V

ac