beautypg.com

Ieee-488.2/scpi syntax and style, Parameters, Units of measure and multipliers – Xantrex Technology XDC User Manual

Page 196: Note, Scpi command hierarchy

background image

SCPI Command Reference
IEEE-488.2/SCPI Syntax and Style

194

Operating Manual for XDC Series Power Supply

IEEE-488.2/SCPI Syntax and Style

Parameters

Units of Measure and Multipliers

Refer to IEEE 488.2, section 7.7.3 for the definition of units of measure.

The default units of measure include:

V (Volt – voltage)

A (Ampere – current)

W (Watt – power)

S (seconds – time)

The supported optional multipliers include:

m (milli)

k (kilo)

SCPI Command Hierarchy

SCPI is an ASCII-based command language designed for use in high-technology test
and measurement equipment. The command structure is organized around common
roots, or nodes, which are the building blocks of SCPI subsystems. An example of a
common root is CALibration, and some of the commands that reside in the
CALibration subsystem are shown below.

CALibration

:CURRent

[:DATA]
:LEVel {MIN|MAX}

[:SECure]

:CODE
:STATe {OFF|ON},
:STATe?

CALibration is the root keyword of the command. CURRent and SECure are
second-level keywords, and DATA, LEVel, CODE, and STATe, are third-level
keywords. A colon (:) is used to separate a command keyword from a lower-level
keyword.

Note The SI standard for these multipliers is specifically lowercase, while the IEEE