These 2 extra steps are shown in the following example.

To set the Under-Voltage Protection:

To set the Over-Current Protection:

Step # Do This

You Will See

1

OVP SET 0V

2

Press repeatedly until the

desired setting appears.

UVP SET 0V

3

UVP SET 0V

4

Use the Voltage knob, the numeric
keypad, or the arrow keys to enter a
value (0–103% of the unit’s rated
voltage).

UVP SET ####V

5

S/D if trip? N

6

Use the arrow keys to select Yes or
No. For this example, Yes is selected.

S/D if trip? Y

7

This setting is saved and the display
returns to its default operating mode.

Step # Do This

You Will See

1

OVP SET 0V

2

Press repeatedly until the

desired setting appears.

OCP SET 0A

3

OCP SET 0A

4

Use the Current knob, the numeric
keypad, or the arrow keys to enter a
value (0–103% of the unit’s rated
current).

OCP SET ####A

5

S/D if trip? N

6

Use the arrow keys to select Yes or
No. For this example, Yes is selected.

S/D if trip? Y

7

This setting is saved and the display
returns to its default operating mode.

PROT SET

ALARMS

PROT SET

ALARMS

ENTER

ENTER

ENTER