Xantrex Technology XDC User Manual
Page 75

Operation
Power Supply Operation
Release 3.0
73
If the alarms are cleared, the system returns to its default operating state. If the alarms
persist, the system prompts OVP SET #####V. The system has shifted to output
protection mode. You can press ENTER to work with the OVP setting or press the
arrow keys to view the other protection settings. See “Set Output Protection” on page
65 for more information.
The possible alarms are:
•
OVP Shutdown
•
UVP Shutdown
•
OCP Shutdown
•
UCP Shutdown
•
OPP Shutdown
•
UPP Shutdown
•
UVP Alarm
•
OCP Alarm
•
UCP Alarm
•
OPP Alarm
•
UPP Alarm
•
Fold Shutdown
•
SenseShutdown
•
Hi Temp Alarm
•
OTP Shutdown
•
AC Off
WARNING- Fire Hazard
If an over-voltage, over-current, or over-power protection error persists without
apparent cause, press OUT ON/OFF to disable the output, and turn the AC switch
OFF. Inspect the load and power supply for evidence of an electrical fault. The power
supply should not be brought back into operation if there is any evidence of an
electrical fire or other safety hazards.