beautypg.com

Electrical specifications—summary, Table e.1 – Xantrex Technology XDC User Manual

Page 230

background image

Specifications and Characteristics
Electrical Specifications—Summary

228

Operating Manual for XDC Series Power Supply

Electrical Specifications—Summary

Table E.1Specifications for 6000 Watt units (10V to 60V Models)

Models

10-600

20-300

30-200

40-150

60-100

Output Ratings:

Output Voltage

1

Output Current

2

Output Power

1. Minimum output voltage is <0.3% of rated voltage at zero output setting.
2. Minimum output current is <0.2% of rated current at zero output setting when measured with rated load resistance.

0–10 V
0–600 A
6000 W

0–20 V
0–300 A
6000 W

0–30 V
0–200 A
6000 W

0–40 V
0–150 A
6000 W

0–60 V
0–100 A
6000 W

Line Regulation:

3

Voltage

(0.01% of Vmax)

Current (0.05% of Imax)

3. For input voltage variation over the AC input voltage range, with constant rated load.

1 mV
300 mA

2 mV
150 mA

3 mV
100 mA

4 mV
75 mA

6 mV
50 mA

Load Regulation:

4

Voltage (0.05% of Vmax + 5 mV)
Current (0.1% of Imax + 20 mA)

4. For 0–100% load variation, with constant nominal line voltage.

10 mV
620 mA

15 mV
320 mA

20 mV
220 mA

25 mV
170 mA

35 mV
120 mA

Meter Accuracy:

Voltage (0.15% of Vmax)
Current (0.5% of Imax)

15 mV
3 A

30 mV
1.5 A

45 mV
1.0 A

60 mV
750 mA

90 mV
500 mA

Output Noise (0–20 MHz):

Voltage (p–p)

75 mV

75 mV

75 mV

75 mV

100 mV

Output Ripple (rms):

Voltage
Current

5

5. Current mode noise is measured from 10% to 100% of rated output voltage, full current, unit in CC mode.

10 mV
3100 mA

10 mV
1600 mA

12 mV
1000 mA

15 mV
750 mA

15 mV
450 mA

OVP Adjustment Range:

(0% to 103% of Vmax)

0–10.3 V

0–20.6 V

0–30.9 V

0–41.2 V

0–61.8 V

Efficiency:

6

6. Typical efficiency at nominal input voltage and full output power.

0.85

0.87

0.87

0.87

0.89