Table E.1Specifications for 6000 Watt units (10V to 60V Models)
Models
10-600
20-300
30-200
40-150
60-100
Output Ratings:
Output Voltage
1
Output Current
2
Output Power
1. Minimum output voltage is <0.3% of rated voltage at zero output setting.
2. Minimum output current is <0.2% of rated current at zero output setting when measured with rated load resistance.
0–10 V
0–600 A
6000 W
0–20 V
0–300 A
6000 W
0–30 V
0–200 A
6000 W
0–40 V
0–150 A
6000 W
0–60 V
0–100 A
6000 W
Line Regulation:
3
Voltage
(0.01% of Vmax)
Current (0.05% of Imax)
3. For input voltage variation over the AC input voltage range, with constant rated load.
1 mV
300 mA
2 mV
150 mA
3 mV
100 mA
4 mV
75 mA
6 mV
50 mA
Load Regulation:
4
Voltage (0.05% of Vmax + 5 mV)
Current (0.1% of Imax + 20 mA)
4. For 0–100% load variation, with constant nominal line voltage.
10 mV
620 mA
15 mV
320 mA
20 mV
220 mA
25 mV
170 mA
35 mV
120 mA
Meter Accuracy:
Voltage (0.15% of Vmax)
Current (0.5% of Imax)
15 mV
3 A
30 mV
1.5 A
45 mV
1.0 A
60 mV
750 mA
90 mV
500 mA
Output Noise (0–20 MHz):
Voltage (p–p)
75 mV
75 mV
75 mV
75 mV
100 mV
Output Ripple (rms):
Voltage
Current
5
5. Current mode noise is measured from 10% to 100% of rated output voltage, full current, unit in CC mode.
10 mV
3100 mA
10 mV
1600 mA
12 mV
1000 mA
15 mV
750 mA
15 mV
450 mA
OVP Adjustment Range:
(0% to 103% of Vmax)
0–10.3 V
0–20.6 V
0–30.9 V
0–41.2 V
0–61.8 V
Efficiency:
6
6. Typical efficiency at nominal input voltage and full output power.
0.85
0.87
0.87
0.87
0.89