Power Supply Operating States

58

Operating Manual for XDC Series Power Supply

Powering

OFF the

Power Supply

From the front panel, the safest method for shutting down the power supply is:

Power Supply Operating States

The power supply has 5 operating states:

Power-On

Output Shutdown

Soft Start

Normal Operation

Calibration

Power-On This is the period between the time that AC power is applied to the supply (AC

breaker turned on) and the time that the power supply is ready for operation. During
this period, the internal circuits are powering up and performing self-tests. At the end
of the Power-On period, the supply is normally in its default Power-On mode with
the output OFF, V

SET

=0 and I

SET

=0.

Output

Shutdown

In this state, the output is disabled and there is no output regardless of power settings.
The power supply can be placed in the Output Shutdown state by a command (via
the front panel or from the programming interface), via the Interlock signal, or from
a protection mechanism. This is also called the Standby mode.

Soft Start In this state, the output power is ramping up gradually towards its target load. This

reduces equipment stress. This state occurs whenever the supply output is set to ON
or a protection state is re-set, and is approximately 2 seconds in duration.

Normal

Operation

This is the normal operating state for the power supply. The power supply is ready
to accept commands.

Calibration This is a service mode that is used to calibrate setpoints and readback levels for

accuracy. Calibration should only be performed by qualified service personnel. For
detailed information, see Appendix A.

Step # Do This

You Will See

1

The OUT OFF annunciator
illuminates; Ouput V and I are 0.

2

Switch the AC power to OFF.

The AC OFF alarm, and then the unit
fades to black.

OFF

ON

OUT