Operation
Power Supply Operation

100

Operating Manual for XDC Series Power Supply

Set V, I, and P

Limits

The voltage, current and power setpoints can be limited to less than the supply rating
range to match the tolerance of connected equipment or any other criteria you may
have.

You can control the voltage, current and power setpoint limits through the SETPT
LIMIT
menu option. Once the limits have been changed from the supply’s default
rated output, settings outside this range are no longer accepted.

To set the voltage limits:

Note Setpoint limits do not apply to the triggered outputs and auto sequence outputs.

Step # Do This

You Will See

1

ERROR MSGS

2

until you see the “SETPT

LIMIT” option

SETPT LIMIT

3

Voltage Limit

4

High 0V

5

Use the Voltage knob, arrow keys,
or numeric keypad to enter a value.
The value must be within 0V to
103% of the unit’s rated voltage.

High #####V

6

Low 0V

The Maximum setting is saved and the
Minimum setting appears.

7

Use the Voltage knob, arrow keys,
or numeric keypad to enter a value.
The value must be within 0V to
103% of the unit’s rated voltage.

Low #####V

8

The setting is saved and the display
returns to its default operating mode.

MENU

ENTER

ENTER

ENTER

ENTER