Specifications and Characteristics
Output Performance Specifications

238

Operating Manual for XDC Series Power Supply

Typical Programming Resolution

Typical Measurement Resolution

Programming Accuracy

1

Readback Accuracy

Front Panel or Remote Digital Interface

Voltage
Current
Power
Over Voltage Protection

0.002% of Vmax
0.002% of Imax
0.05% of Pmax
0.002% of Vmax

Remote Analog Programming Interface

Voltage
Current

0.002% of Vmax
0.002% of Imax

Front Panel or Remote Digital Interface

Voltage
Current
Power

0.002% of Vmax
0.002% of Imax
0.05% of Pmax

Remote Analog Programming Interface

Voltage
Current

0.002% of Vmax
0.002% of Imax

Front Panel or Remote Digital Interface

Voltage Programming
Current Programming
Power Programming
Over voltage
Programming

0.1% of Vmax
0.5% of Imax
0.5% of Pmax
0.1% of Vmax

Remote Analog Programming Interface

Voltage Programming
Current Programming

0.2% of Vmax
0.5% of Imax

1. Accuracy specifications apply for settings in range of 1% to 100% of rated output

Front Panel or Remote Digital Interface

Voltage Readback
Current Readback
Power Readback

0.15% of Vmax
0.5% of Imax
0.5% of Pmax

Remote Analog Programming Interface

Voltage Readback
Current Readback

0.3% of Vmax
0.5% of Imax