beautypg.com

Programming sequences, Select sequence to program, Editing the sequence – Xantrex Technology XDC User Manual

Page 140: Setting sequence repetitions

background image

Remote Operation
SCPI Commands for Digital Interfaces

138

Operating Manual for XDC Series Power Supply

Programming

Sequences

Select Sequence to Program

PROGram:NAME

is a number between 1 and 10 that corresponds to the

number of the sequence.

Define the name of the program to be selected. If already

exists, then that existing program is selected. If the program name does not exist,
then the new name is selected, but no program is defined by this selection.

Editing the Sequence

To edit an existing step or to program new steps, use the following commands:
PROG:STEP[:EDIT] [[[[[]
,],],],{

Any of the step parameters may be omitted, in which case the default parameters will
be used. The defaults are 0 V, 0 A, 0 W, 0 V, 10 ms.

To insert a step between commands in an existing program, use this command:
PROG:STEP:INS
,,,,{

The step number is where the inserted step is to be located. The existing step and all
following steps at that location are moved down.

In both the edit and insert commands:

ranges from 1 to 99.

milliseconds. It ranges from 10ms to 99 hours.

TRIG may be entered instead of a step duration. In this case, the unit will hold

the output levels at that step until a trigger signal is supplied.

Setting Sequence Repetitions

PROG:REP {ONCE ||FOR|INF}

ONCE will run the sequence once and return it to its STOP condition.

ranges from 1 to 9999. It will run the sequence the

number of times specified before putting it into the STOP condition.

FORever and INFinity cause the sequence to repeat forever. A query will return

9.9E37, representing INFinity.