Enter current data, Maximum calibration level, Analog programming interface 0-5v range – Xantrex Technology XDC User Manual

Page 190: Minimum calibration level, Enter voltage data

background image

Calibration
Remote Interface Calibration Procedure

188

Operating Manual for XDC Series Power Supply

3. Enter current data

Enter the current read from the external DVM via the shunt.

CAL:OUTP:CURR:DATA

4. Maximum calibration level

Set the output current to 90% by sending the command:

CAL:OUTP:CURR:LEV MAX

5. Enter current data

Enter the current read from the shunt via the external DVM.

CAL:OUTP:CURR:DATA

6. Power supply calculates and stores calibration constants.

Analog

Programming

Interface 0-5V

Range

To set up to calibrate the analog programming interface, you will need a DC power
source capable of outputting 0 to 5V and a DVM.

Table 4.2 “Analog Programming Pins”

Analog Programming Interface Voltage Programming Calibration

1. Connect the power source across the voltage programming lines, Pins B3 and

B1(GND). Attach a DVM across the voltage programming lines as well.

2. Minimum calibration level

Set the input to the programming lines to approximately 0.5V (10% of full

scale).

Set the power supply to receive 5V analog voltage programming calibration data

with the command:

CAL:ANAL:5V:PROG:VOLT:LEV MIN

3. Enter voltage data

Enter the voltage at the voltage programming lines, read from the external DVM.

CAL:ANAL:5V:PROG:VOLT:DATA

4. Maximum calibration level

Set the input to the programming lines to approximately 4.5V (90% of full

scale).

Set the power supply to receive 5V analog voltage programming calibration data

with the command:

CAL:ANAL:5V:PROG:VOLT:LEV MAX