Remote Operation
SCPI Commands for Digital Interfaces

146

Operating Manual for XDC Series Power Supply

REGulating Sub-Register

This describes the regulating mode. If none of these bits is active, the output
unregulated (UNRegulated) bit is active in the questionable status register.

Table 4.10 REGulating Sub-Register

SHUTdown Sub-Register

Describes the cause of the power supply shutting down. More than one bit may be
active, and multiple actions will be required to restart the unit. The protection
shutdown sub-register indicates which protection mechanisms have caused the
power supply to shutdown.

Table 4.11 SHUTdown Sub-Register

Bit

Bit Weight Bit Name

Description

0

1

CV

The power supply is regulating in Constant
Voltage mode.

1

2

CC

The power supply is regulating in Constant
Current mode.

2

4

CP

The power supply is regulating in Constant
Power mode.

Bit

Bit Weight Bit Name

Description

0

1

PROTectio
n Summary

The power supply is shut down by a power
supply protection mechanism.

1

2

INTerlock

The power supply is shut down by INTerlock
signal.

2

4

COMMand

The power supply is shut down by a command.