REGulating Sub-Register
This describes the regulating mode. If none of these bits is active, the output
unregulated (UNRegulated) bit is active in the questionable status register.
Table 4.10 REGulating Sub-Register
SHUTdown Sub-Register
Describes the cause of the power supply shutting down. More than one bit may be
active, and multiple actions will be required to restart the unit. The protection
shutdown sub-register indicates which protection mechanisms have caused the
power supply to shutdown.
Table 4.11 SHUTdown Sub-Register
Bit
Bit Weight Bit Name
Description
0
1
CV
The power supply is regulating in Constant
Voltage mode.
1
2
CC
The power supply is regulating in Constant
Current mode.
2
4
CP
The power supply is regulating in Constant
Power mode.
Bit
Bit Weight Bit Name
Description
0
1
PROTectio
n Summary
The power supply is shut down by a power
supply protection mechanism.
1
2
INTerlock
The power supply is shut down by INTerlock
signal.
2
4
COMMand
The power supply is shut down by a command.