beautypg.com

Scpi – Xantrex Technology XDC User Manual

Page 113

background image

Remote Operation

Remote Analog Operation

Release 3.0

111

Next select analog programming as the remote control interface.

Your options are

Analog V & I - voltage and current programmed via the analog interface

Analog V - voltage programmed via the analog interface; current set via front panel

Analog I - current programmed via the analog interface; voltage set via front panel

Press the LCL/RMT button to begin remote operation via the analog interface.

SCPI

To select which setpoints to control via analog programming lines, use the
command:
SYST:REM:SOUR {AVOL|ACUR|AVC}

Where

AVOL (Analog VOLtage) selects only voltage to be programmed via the analog

programming lines

ACUR (Analog CURrent) selects only current to be programmed via the analog

programming lines

AVC (Analog Voltage and Current) selects voltage and current to be programmed

via the analog programming lines

To select the voltage level:
SYST:COMM:APR:LEV {5|10}

Where

“5” is the 0-5V range, and
“10” is the 0-10V range

To put the unit into remote control:
SYST:REM:STAT REM

Step # Do This

You Will See

1

ERROR MSGS

2

4 times

REMOTE SELECT

3

RS-232

4

or

Select desired option.

Analog V&I,
Analog V, or
Analog I

5

Setting is saved.

MENU

ENTER

ENTER