Voltage sub-register, Current sub-register, Power sub-register – Xantrex Technology XDC User Manual
Page 154: Table 4.16, Table 4.17, Table 4.18, Table 4.16, table 4.17, table 4.18, and
Remote Operation
SCPI Commands for Digital Interfaces
152
Operating Manual for XDC Series Power Supply
VOLTage Sub-Register
This shows whether the present voltage level is over or under the specified trip limit.
Table 4.16 VOLTage Sub-Register
CURRent Sub-Register
This shows whether the present current level is over or under the specified trip limit.
Table 4.17 CURRent Sub-Register
POWer Sub-Register
This shows whether the present power level is over or under the specified trip limit.
Table 4.18 POWer Sub-Register
Bit
Bit Weight
Bit Name
Description
0
1
Over VOLtage
Set if the supply’s output voltage
exceeds the over-voltage trip level,
either user-specified variable trip limit,
or the fixed trip limit.
1
2
Under VOLtage
Set if the supply’s output voltage is less
than the user-specified under-voltage
trip level (variable trip limit) and the
supply is in Operation state.
Bit
Bit Weight
Bit Name
Description
0
1
Over CURrent
Set if the supply’s output current is
greater than the user-specified
over-current trip level (variable trip limit)
and the supply is in Operation state.
1
2
Under CURrent
Set if the supply’s output current is less
than the user-specified under current
trip level (variable trip limit) and the
supply is in Operation state.
Bit
Bit Weight
Bit Name
Description
0
1
Over POWer
Set if the supply’s output power is
greater than the user-specified
over-power trip level (variable trip limit),
and the supply is in Operation state.
1
2
Under POWer
Set if the supply’s output power is less
than the user-specified under-power trip
level (variable trip limit), and the supply
is in Operation state.