Remote Operation
SCPI Commands for Digital Interfaces

152

Operating Manual for XDC Series Power Supply

VOLTage Sub-Register

This shows whether the present voltage level is over or under the specified trip limit.

Table 4.16 VOLTage Sub-Register

CURRent Sub-Register

This shows whether the present current level is over or under the specified trip limit.

Table 4.17 CURRent Sub-Register

POWer Sub-Register

This shows whether the present power level is over or under the specified trip limit.

Table 4.18 POWer Sub-Register

Bit

Bit Weight

Bit Name

Description

0

1

Over VOLtage

Set if the supply’s output voltage
exceeds the over-voltage trip level,
either user-specified variable trip limit,
or the fixed trip limit.

1

2

Under VOLtage

Set if the supply’s output voltage is less
than the user-specified under-voltage
trip level (variable trip limit) and the
supply is in Operation state.

Bit

Bit Weight

Bit Name

Description

0

1

Over CURrent

Set if the supply’s output current is
greater than the user-specified
over-current trip level (variable trip limit)
and the supply is in Operation state.

1

2

Under CURrent

Set if the supply’s output current is less
than the user-specified under current
trip level (variable trip limit) and the
supply is in Operation state.

Bit

Bit Weight

Bit Name

Description

0

1

Over POWer

Set if the supply’s output power is
greater than the user-specified
over-power trip level (variable trip limit),
and the supply is in Operation state.

1

2

Under POWer

Set if the supply’s output power is less
than the user-specified under-power trip
level (variable trip limit), and the supply
is in Operation state.