Figure 4.2 schematic for user line interface, Table 4.2, Analog programming pins – Xantrex Technology XDC User Manual
Page 111: Figure 4.2, Schematic for user line interface, D table 4.2
Remote Operation
Remote Analog Operation
Release 3.0
109
Figure 4.2 Schematic For User Line Interface
Table 4.2 Analog Programming Pins
The analog setpoint and readback pins may be configured to work in either a 0–5V
range or 0–10V range.
The programming lines have their own isolated power source (10mA max), and this
power can be looped back to power the user lines, if required. Connect the pins as
shown in Table 4.3.
Pin #
Function
Input/Output
B1
Analog Programming (GND)
Output
B2
12V (unregulated) 10mA max
Output
B3
Voltage Setpoint (0–5/10V)
Input
B4
Current Setpoint (0–5/10V)
Input
B5
Voltage Readback (0–5/10V)
Output
B6
Current Readback (0–5/10V)
Output
Vf = 1.3V TYP, 1.5V MAX
If = 10mA Recommended, 90mA MAX
CNY17-2
CNY17-2
508 Ohm
0.4W
508 Ohm
0.4W
CNY17-2
CHASSIS POTENTIAL
ISOLATED USER LINES
CNY17-2
USER LINES