Remote Operation

Remote Analog Operation

Release 3.0

109

Figure 4.2 Schematic For User Line Interface

Table 4.2 Analog Programming Pins

The analog setpoint and readback pins may be configured to work in either a 0–5V
range or 0–10V range.

The programming lines have their own isolated power source (10mA max), and this
power can be looped back to power the user lines, if required. Connect the pins as
shown in Table 4.3.

Pin #

Function

Input/Output

B1

Analog Programming (GND)

Output

B2

12V (unregulated) 10mA max

Output

B3

Voltage Setpoint (0–5/10V)

Input

B4

Current Setpoint (0–5/10V)

Input

B5

Voltage Readback (0–5/10V)

Output

B6

Current Readback (0–5/10V)

Output

Vf = 1.3V TYP, 1.5V MAX
If = 10mA Recommended, 90mA MAX

CNY17-2

CNY17-2

508 Ohm
0.4W

508 Ohm
0.4W

CNY17-2

CHASSIS POTENTIAL

ISOLATED USER LINES

CNY17-2

USER LINES