beautypg.com

30 minute drift, 8 hour drift temperature stability, Temperature coefficients – Xantrex Technology XDC User Manual

Page 241: Analog programming interface

background image

Specifications and Characteristics

Output Performance Specifications

Release 3.0

239

30 Minute Drift

1

8 Hour Drift Temperature Stability

2

Temperature Coefficients

Analog Programming Interface

Voltage

0.04% of Vmax

Current

0.6% of Imax

Power

6000W: 1% of Pmax
12000W: 2% of
Pmax

1. At 25°C ±5°C, with full power load

Voltage

0.02% of Vmax

Current

6000W: 0.04% of Imax
12000W: 0.05% of imax
12000W 600V model: 0.08% of Imax

Power

0.1% of Pmax

2. At 25°C ±5°C after 30 minutes full load operation

Front Panel or Remote Digital Interface

Voltage Programming
Current Programming
Power Programming
Voltage Readback
Current Readback
Power Readback

0.04% of Vmax

/°C

0.06% of Imax

/°C

0.1% of Pmax

/°C

0.04% of Vmax

/°C

0.06% of Imax

/°C

0.1% of Pmax

/°C

Remote Analog Programming Interface

Voltage Programming
Current Programming
Voltage Readback
Current Readback

0.04% of Vmax

/°C

0.06% of Imax

/°C

0.04% of Vmax

/°C

0.06% of Imax

/°C

Programming Lines, Impedance
0-5 V

dc

range

0-10 V

dc

range

>30 kOhm
>30 kOhm

Readback Lines, Impedance
0-5 V

dc

range

0-10 V

dc

range

<500 Ohm
<1 kOhm

Isolation, all program and readback lines

300 Vdc with respect to chassis potential or negative output