Remote Operation
Remote Analog Operation

110

Operating Manual for XDC Series Power Supply

Table 4.3 Analog Pin Connections for Power Loop Back

Remote Interlock Using a Contact Closure

The interlock input may be configured for use with an external voltage free contact.
Connect pins as shown:

Table 4.4 Analog Pin Connections with a Contact Closure

Closing an external contact across the interlock pins A4/A5 will then enable the unit.
Opening the contact will disable the supply output.

Configure

Analog

Control

You may configure the analog programming lines to work in either a 0 to 5V range
or a 0 to10V range. You may also select whether the voltage, current or both are
controlled with the programming lines. If you select only voltage or only current, the
other will be controlled via the front panel.

Front Panel

First, configure the analog programming lines.

Programming Line Pin #

User Line Pin #

B1

to

A7

B2

to

A6

Programming Line Pin #

User Line Pin #

B2

to

A4

B1

to

A5

Step # Do This

You Will See

1

ERROR MSGS

2

5 times

1

1. You can also press MENU 5 times.

REMOTE CONFIG

3

RS-232 Cfg

4

Analog Cfg

5

Input 0-5V

6

or

Select the input range.

0-5V or
0-10V

7

Setting is saved and menu is exited.

MENU

ENTER

ENTER

ENTER