Operation
Power Supply Operation

70

Operating Manual for XDC Series Power Supply

To set the Under-Power Protection:

Fold Protection options are:

None: Fold protection disabled

CC: Shutdown on entering CC mode

CV: Shutdown on entering CV mode

CP: Shutdown on entering CP mode

A programmable delay time causes the supply to wait before shutting down the
output.

Step # Do This

You Will See

1

OVP SET 0V

2

Press repeatedly until the

desired setting appears.

UPP SET 0W

3

UPP SET 0W

4

Use both the Current and Voltage
knobs, or the numeric keypad, or the
arrow keys to enter a value (must be
between 0W and 103% of the unit’s
rated power).

UPP SET ####W

5

S/D if trip? N

6

Use the arrow keys to select Yes or
No. For this example, Yes is selected. S/D if trip? Y

7

This setting is saved and the display
returns to its default operating mode.

PROT SET

ALARMS

PROT SET

ALARMS

ENTER

ENTER