beautypg.com

Absolute position detection system – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 356

background image

15 - 49

15. ABSOLUTE POSITION DETECTION SYSTEM

(2) Sequence program example

(a) Conditions

1) When the servo-on signal and power supply GND are shorted, the ABS data is transmitted at

power-on of the servo amplifier or on the leading edge of the RUN signal after a PC reset
operation (PC-RESET). The ABS data is also transmitted when an alarm is reset or when an
emergency stop is reset.

2) If a checksum mismatch is detected in the transmitted data, data transmission is retried up to

three times. If the checksum mismatch still persists after the retries, the ABS checksum error
occurs (Y3A ON).

3) The following time periods are measured. If the ON/OFF state does not change within the

specified time, the ABS communication error occurs change within the specified time, the ABS
communication error occurs (Y39 ON):
ON period of ABS transfer mode (Y31)
ON period of ABS request (Y32)
OFF period of reading to send ABS data (X22)

(b) Device list

X input contact

Y output contact

X20

ABS bit 0 / positioning completion

Y30

Servo-on

X21

ABS bit 1 / zero speed

Y31

ABS transfer mode

X22

Reading to send ABS data / limiting torque Y32

ABS request

X23

Servo alarm

Y33

Alarm reset

X24

Alarm reset

X34

(Note 2)

Electromagnetic brake output

X25

Servo emergency stop

Y35

(Note 1)

Clear

X26

Servo-on

Y38

Servo alarm

X27

Home position return start

Y39

ABS communication error

X28

Operation mode I

Y3A

ABS checksum error

X29

Operation mode II

D register

M contact

D0

ABS data transmission counter

M5

ABS data transmission start

D1

Checksum transmission counter

M6

Sum check completion

D2

Checksum addition register

M7

Sum check mismatch

D3

ABS data: Lower 16 bits

M8

ABS data ready

D4

ABS data: Upper 16 bits

M9

Transmission data read enabled

D5

ABS data 2-bit receiving buffer

M10

Checksum 2 bits read completion

D6

Check data in case of checksum error

M11

ABS 2 bits read completion

D7

Number of retries

M12

ABS 2 bits request

D8

Forward rotation direction

M13

Servo-on request

D9

Home position address: Lower 16 bits

M14

Servo alarm

D10

Home position address: Upper 16 bits

M15

ABS data transmission retry start pulse

D11

Drive unit ready data

M16

Retry flag set

D12

Home position return completion data

M17

Retry flag reset

D110

Received shift data: Lower 16 bits

M18

PLS processing command

D111

Received shift data: Upper 16 bits

M20

(Note 1)

Clear (CR) ON timer request

T timer

M21

(Note 1)

Data set type home position return request

T0

ABS transmission mode timer

T1

ABS request response timer

M22

Home position return processing
instruction

T2

Retry wait timer

T3

ABS data send reading response timer

M23

Current position change processing
instruction

T10

(Note 1)

Clear (CR) ON timer

M24

Current position change flag

T200

Transmitted data read 10ms delay timer

C counter

C0

ABS data receive times counter

C1

Checksum receive times counter

C2

Retry counter

Note 1. Required for data set type home position return.

2. Required for electromagnetic brake output.

3)

1)

2)

4)