beautypg.com

Absolute position detection system – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 319

background image

15 - 12

15. ABSOLUTE POSITION DETECTION SYSTEM

(2) Transmission error

(a) Time-out warning(AL.E5)

In the ABS transfer mode, the time-out processing shown below is executed at the servo. If a time-
out error occurs, an ABS time-out warning (AL.E5) is output.
The ABS time-out warning (AL.E5) is cleared when the ABS transfer mode (ABSM) changes from
OFF to ON.
1) ABS request OFF-time time-out check (applied to 32-bit ABS data in 2-bit units check sum)

If the ABS request signal is not turned ON by the programmable controller within 5s after the
send data ready (TLC) is turned ON, this is regarded as a transmission error and the ABS time-
out warning (AL.E5) is output.

OFF

ON

OFF

ON

OFF

ON

5s

ABS transfer mode

ABS request

Send data ready

AL.E5 warning

Signal is not turned ON

No

Yes

2) ABS request ON-time time-out check (applied to 32-bit ABS data in 2-bit units check sum)

If the ABS request signal is not turned OFF by the programmable controller within 5s after the
send data ready (TLC) is turned OFF, this is regarded as the transmission error and the ABS
time-out warning (AL.E5) is output.

OFF

ON

OFF

ON

OFF

ON

5s

ABS transfer mode

ABS request

Send data ready

AL.E5 warning

Signal is not turned OFF

No

Yes