beautypg.com

10 grounding, Signals and wiring, Warning – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 104

background image

3 - 57

3. SIGNALS AND WIRING

3.10 Grounding

WARNING

Ground the servo amplifier and servo motor securely.

To prevent an electric shock, always connect the protective earth (PE) terminal of

the servo amplifier with the protective earth (PE) of the control box.

The servo amplifier switches the power transistor on-off to supply power to the servo motor. Depending on
the wiring and ground cablerouting, the servo amplifier may be affected by the switching noise (due to
di/dt and dv/dt) of the transistor. To prevent such a fault, refer to the following diagram and always
ground.
To conform to the EMC Directive, refer to the EMC Installation Guidelines (IB(NA)67310).

Control box

Servo amplifier

L

1

L

2

L

3

L

11

L

21

CN1A CN1B

Li

ne f

ilt

er

NFB

MC

Protective earth(PE)

CN2

U

V

W

Outer
box

Servo motor

Ensure to connect it to PE
terminal of the servo amplifier.
Do not connect it directly to
the protective earth of
the control panel.

Encoder

M

U

V

W

(Note)
Power supply
3-phase
200 to 230VAC,
1-phase
230VAC or
1-phase
100 to 120VAC

Note. For 1-phase 230VAC, connect the power supply to L

1

L

2

and leave L

3

open.

Pr

o

g

ra

mma

b

le

cont

ro

ller

There is no L

3

for 1-phase 100 to 120VAC power supply.