beautypg.com

Absolute position detection system, B) fx, 32mt (fx – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 343: 1pg)

background image

15 - 36

15. ABSOLUTE POSITION DETECTION SYSTEM

(b) FX

2N

-32MT (FX

2N

-1PG)

3.3k

3.3k

3.3k

CN1B

N

COM2

Y4

Y5

Y6

Y10

24

S/S

DOG

STOP

VIN

FP

COM0

RP

COM1

CLR

L

Power supply

FX

2N

-32MT

SG

10

DO1

4

ZSP 19

TLC

6

ALM 18

RD

EMG

15

SON

5

ABSM

8

ABSR

9

RES 14

DOG

SD

FX

2N

-1PG

Servo amplifier

COM

X1

X2

X3

X4

X5

X6

X7

X10

X11

X12

X13

X14

X15

COM1

Y0

X0

Y1

Y2

Y3

Y7

COM3

Y11

Y12

Y13

RA2

COM

13

PGO

PGO

PP

3

SG

20

NP

12

SG

10

CR

8

P15R

4

OP

14

SD

SD

24V

VDD

3

Plate

24V

OPC 11

CN1A

CN1A

19

3.3k

JOG( )

JOG( )

Alarm reset

Servo-on

Position start

Position stop

Home position return start

1PG error reset

ABS bit 0/Completion of positioning

ABS bit 1/Zero speed

Send data ready/Torque limit control

Alarm

Servo ready

Emergency stop

(Note 2)

Electromagnetic

brake output

(Note 3)

Servo alarm

ABS communication

error

ABS check sum error

Servo-on

ABS transfer mode

ABS request

Alarm reset

(Note 1)

Pulse train for forward rotation

Pulse train for reverse rotation

Clear

Z-phase pulse

Note 1. To be connected for the dog type home position setting. At this time, do not connect the portions marked (Note 2).
2. To be connected for the data set type home position setting. At this time, do not connect the portions marked
(Note 1).
3. The electromagnetic brake interlock (MBR) should be controlled by connecting the programmable controller
output to a relay.

15V