beautypg.com

Options and auxiliary equipment, 2) connection diagram – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 258

background image

13 - 33

13. OPTIONS AND AUXILIARY EQUIPMENT

(2) Connection diagram

RA2

EMG

SON

C

B

R/L

11

Three-phase

200 to 230VAC

S/L

21

T/L

31

R2/L1

S2/L

22

R2/L

12

T2/L

32

S2/L2

(Note 3)

SG

P24

SD

RDYB

RDYA

RSO

SE

A

T2/L3

R/L

11

S/L

21

T/MC1

RES

SD

(Note
1)

L

11

RES

SG

SG

ALM

VIN

U

V

W

SG

(Note 1)

(Note1)

(Note 3)

RA1

EMG

SON

(Note 2)

RA3

RA2

RA1

RA4

24VDC

power

supply

U

V

W

Thermel
relay

OHS2

OHS1

CN2

MC

NFB

FR-CVL

FR-CV

MC

RA2 RA3 RA4 EMG OFF

ON

RESET

SK

MC

(Note 2) (Note 1)

Servo motor

Servo amplifier

(Note 1)

N

L

21

P

P/L

P/L

P

1

(Note 5)

(Note 4)

Note 1. Configure a sequence that will shut off main circuit power in the following cases:

Alarm occurred in the FR-CV or the servo amplifier.

Emergency stop is activated.

2. For the servo motor with thermal relay, configure a sequence that will shut off main circuit power when the thermal relay

operates.

3. For the servo amplifier, configure a sequence that will switch the servo on after the FR-CV is ready.
4. For 7kW or less servo amplifier, always remove the wiring (3.5kW or less: across P-D, 5k

7kW: across P-C) of built-in

regenerative brake resistor.

5. For the amplifiers of 11k to 22kW, make sure to connect across P-P1. (Wiring is factory-connected.)

(3) Wires used for wiring

(a) Wire sizes

1) Across P-P, N-N

The following table indicates the connection wire sizes of the DC power supply (P, N terminals)
between the FR-CV and servo amplifier. The used wires are based on the 600V vinyl wires.

Total of servo amplifier capacities [kW]

Wires[mm

2

]

1 or less

2

2

3.5

5

5.5

7

8

11

14

15

22

22

50