9 emc filter, Options and auxiliary equipment, 2) connection example – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual
Page 277: 3) outline drawing
13 - 52
13. OPTIONS AND AUXILIARY EQUIPMENT
13.2.9 EMC filter
For compliance with the EMC directive of the EN Standard, it is recommended to use the following filter:
Some EMC filters are large in leakage current.
(1) Combination with the servo amplifier
Recommended filter
Servo amplifier
Model
Leakage current [mA]
Mass [kg]([lb])
MR-J2S-10A to MR-J2S-100A
MR-J2S-10A1 to MR-J2S-40A1
SF1252
38
0.75(1.65)
MR-J2S-200A MR-J2S-350A
SF1253
57
1.37(3.02)
MR-J2S-500A
(Note)
HF3040A-TM
1.5
5.5(12.13)
MR-J2S-700A
(Note)
HF3050A-TM
1.5
6.7(14.77)
MR-J2S-11KA
(Note)
HF3060A-TMA
3.0
10.0(22.05)
MR-J2S-15KA
(Note)
HF3080A-TMA
3.0
13.0(28.66)
MR-J2S-22KA
(Note)
HF3100A-TMA
3.0
14.5(31.97)
Note: Soshin Electric A surge protector is separately required to use any of these EMC filters. (Refer to the EMC Installation
Guidelines.)
(2) Connection example
NFB
L
1
L
2
L
3
L
11
L
21
L
1
L
2
L
3
LINE
LOAD
EMC filter
Servo amplifier
(Note 1)
Power supply
(Note 2)
Note 1. For 1-phase 230VAC power supply, connect the power supply to L
1
,L
2
and leave L
3
open.
There is no L
3
for 1-phase 100 to 120VAC power supply.
2. Connect when the power supply has earth.
L
1
L
2
L
3
MC
(3) Outline drawing
23.0(0.906)
LAB
E
L
LI
N
E
LOA
D
16
8.0(
6
.6
1
4
)
L1'
L2'
L3'
L1
L2
L3
149.5(5.886)
LINE
(input side)
LOAD
(output side)
14
0.0(
5
.5
1
2
)
15
6.0(
6
.1
4
2
)
16.0(0.63)
42.0
8.5
SF1252
LAB
E
L
LI
N
E
LOA
D
16
8.0(
6
.6
1
4
)
L1'
L2'
L3'
L1
L2
L3
209.5(8.248)
LINE
(input side)
LOAD
(output side)
14
0.0(
5
.5
1
2
)
15
6.0(
6
.1
4
2
)
49.0
8.5
SF1253
[Unit: mm(in)]
(0.335)
(1.654)
(0.335)
(1.929)
6.0(0.236)
6.0(0.236)