15. ABSOLUTE POSITION DETECTION SYSTEM

(d) Slot arrangement

The sequence programs presented in this section show I/O numbers (X, Y) assuming the
arrangement of modules on the main base unit is as illustrated below. A1SD71 is mounted at I/O
slots 0 and 1, a 16-point input module at slot 2, and 16-point output module at slot 3. If the actual
arrangement of the modules differs from this arrangement, change the X and Y numbers
accordingly.
The numbers of the devices (M, D, T, etc.) used in the program can be changed as required.

A1S

CPU

0

7

1

2

3

4

5

6

A1SD71

I/O slot No.

Example arrangement of modules

[Numbers used] X, X0-X, Y2F

16-point input module

16-point output module

Power

supply

(e) Points

1) The A1SD71 has 48 I/O points and occupies 2 slots. For I/O allocation using the GPP function,

follow the instructions given below.
First slot: Vacant slot 16 points
Second slot: Special function module 32 points

2) To execute the FROM/TO instruction for the A1SD71, use the head I/O number of the second

slot.

A1S

CPU

A1SD71

X,Y000

to

X,Y00F

X,Y010

to

X,Y02F

X30 to X3F

Y40 to Y4F

I/O numbers to be set
with FROM/TO instruction

16-

poi

nt i

n

p

u

t

mo

dul

e

16-

poi

nt ou

tpu

t

mo

dul

e

Note: The program example given
in (3) in this section is for 1-axis
control. Slot allocations are as
illustrated to the left. To use the
system for 2-axis control,
increase the number of I/O
points.

Therefore, the I/O number to be set with the FROM/TO instruction is head I/O number allocated
to the A1SD71 010

H

.

3) By setting "0 point of vacant slot" for the first slot of the A1SD71 in the "I/O allocation" of the

GPP function, the 16 points in the first slot can be saved.
In this case, the I/O number to be set with the FROM/TO instruction is the same number as the
head I/O number allocated to the A1SD71.

A1S

CPU

A1SD71

X,Y000

to

X,Y00F

I/O numbers to be set with FROM/TO instruction