15. ABSOLUTE POSITION DETECTION SYSTEM

(e) Electromagnetic brake output

During ABS data transfer (for several seconds after the servo-on (SON) is turned on), the servo
motor must be at a stop.
Set "1 1 " in parameter No. 1 of the servo amplifier to choose the electromagnetic brake interlock
(MBR).

Y1

X1

Y4

Electromagnetic brake output

ABS transfer
mode

Brake (MBR)

(f) Positioning completion

To create the status information for servo positioning completion.
During ABS data transfer (for several seconds after the servo-on (SON) is turned on), the servo
motor must be at a stop.

Y1

X0

M

Y1

Completion of servo positioning

ABS transfer
mode

Positioning
completion

ABS transfer
mode

(g) Zero speed

To create the status information for servo zero speed.
During ABS data transfer (for several seconds after the servo-on (SON) is turned on), the servo
motor must be at a stop.

Y1

X1

M

Y1

Servo zero speed

ABS transfer
mode

Zero speed

ABS transfer
mode

(h) Torque limiting

To create the status information for the servo torque limiting mode.
During ABS data transfer (for several seconds after the servo-on (SON) is turned on), the torque
limiting must be off.

Y1

X2

M

Servo torque limiting mode

ABS transfer
mode

Torque limiting mode