*OP1 Function selection 1

Used to select the input signal filter, pin CN1B-19 function and

absolute position detection system.

Input signal filter
If external input signal causes chattering
due to noise, etc., input filter is used to
suppress it.
0:None
1:1.777[ms]
2:3.555[ms]
3:5.333[ms]

CN1B-pin 19's function selection
0:Zero Speed detection (ZSP)
1:Electromagnetic brake interlock (MBR)

Selection of absolute position detection system
(Refer to Chapter 15)
0: Used in incremental system
1: Used in absolute position detection system

CN1B-pin 18's function selection
0: Alarm (ALM)
1: Dynamic brake interlock (DB)
When using the external dynamic brake with 11kW
or more, make dynamic brake interlock (DB) valid.