beautypg.com

Parameters – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 126

background image

5 - 7

5. PARAMETERS

Class

No.

Symbol

Name and function

Initial

value

Unit

Setting

range

Control

mode

2

ATU

Auto tuning

Used to selection the response level, etc. for execution of auto tuning.
Refer to Chapter 7.

Response level setting

If the machine hunts or generates
large gear sound, decrease the
set value.
To improve performance, e.g.
shorten the settling time, increase
the set value.

Set

value

Response

level

1

Low

response

Middle

response

High

response

Gain adjustment mode selection
(For more information, refer to Section 7.1.1.)

Machine resonance
frequency guideline

15Hz

2

20Hz

3

25Hz

4

30Hz

5

35Hz

6

45Hz

7

55Hz

8

70Hz

9

85Hz

A

105Hz

B

130Hz

C

160Hz

D

200Hz

E

240Hz

F

300Hz

Set

value

Gain adjustment mode

0

Description

1

3

Simple manual adjustment.

4

Manual adjustment of all gains.

Interpolation mode

Fixes position control gain 1
(parameter No. 6).

Auto tuning mode 1

Fixes the load inertia moment
ratio set in parameter No. 34.
Response level setting can be
changed.

Manual mode 1
Manual mode 2

2

Auto tuning mode 2

Ordinary auto tuning.

0

0

7kW or

less: 0105

11kW or

more: 0102

Refer to
Name
and
function
column.

P S

3

CMX

Electronic gear numerator

Used to set the electronic gear numerator value.
For the setting, refer to Section 5.2.1.
Setting "0" automatically sets the resolution of the servo motor
connected.
For the HC-MFS series, 131072 pulses are set for example.

1

0
1

to

65535

P

B

asi

c p

ara

m

et

ers

4

CDV

Electronic gear denominator

Used to set the electronic gear denominator value.
For the setting, refer to Section 5.2.1.

1

1

to

65535

P