3. SIGNALS AND WIRING

Terminal box inside (HA-LFS15K2 HA-LFS-22K2)

Earth terminal M6 screw

Thermal sensor terminal
block (OHS1, OHS2)
M4 screw

Cooling fan terminal
block (BU, BV, BW)
M4 screw

Moter power supply
terminal block
(U, V, W) M8 screw

Encoder connector
MS3102A20-29P

U

V

W

BU

BV

OHS1OHS2

BW

Terminal block signal arrangement

Power supply connection screw size

Servo motor

Power supply connection screw size

HA-LFS15K2
HA-LFS22K2

M8

Signal Name

Abbreviation

Description

Power supply

U V W

Connect to the motor output terminals (U, V, W) of the servo amplifier.
Supply power which satisfies the following specifications.

HA-LFS11K2

Item

Description

Voltage/frequency

single-phase 200 to 220VAC, 50Hz
single-phase 200 to 230VAC, 60Hz

Power consumption [W]

42(50Hz)/54(60Hz)

Rated voltage [V]

0.12(50Hz)/0.25(60Hz)

HA-LFS15K2/22K2

Item

Description

Voltage/frequency

Three-phase 200 to 220VAC, 50Hz
Three-phase 200 to 230VAC, 60Hz

Power consumption [W]

32(50Hz)/40(60Hz)

Rated voltage [V]

0.30(50Hz)/0.25(60Hz)

Cooling fan

(Note)
BU BV BW

Motor thermal relay OHS1 OHS2 OHS1-OHS2 are opened when heat is generated to an abnormal temperature.

Earth terminal

For grounding, connect to the earth of the control box via the earth terminal of the servo
amplifier.

Note. There is no BW when the HA-LFS11K2 is used.