3) setting items for scc command, 24 (3) setting items for scc command – Yaskawa MP2000 Series: User's Manual for Motion Programming User Manual
Page 131
8 Command Reference
8.1.5 S-curve Time Constant Change (SCC)
8-24
(3) Setting Items for SCC Command
Motion Image
Specify a numerical value or register for the S-curve time constant of each axis using an SCC command.
The reference range of the S-curve time constant depends on the motion module to be used:
• For SVA-01, PO-01, and SVR modules, the reference range is specified by motion setting parameter
OW
3A (Filter time constant).
• For built-in SVB and SVB-01 modules, the reference range is specified by the SERVOPACK parameter
Average Movement Time.
The following table shows the reference range of S-curve time constants for each motion module model.
• If a reference value of more than 6553 ms is input, a motion program alarm will occur regardless of the motion module
model.
• If a reference value exceeds the upper limit (511 to 6553 ms) when using a built-in SVB or SVB-01 module, bit 1 of
motion monitoring parameter IL
02 is set to 1 (Set parameter error), and the upper limit (510 ms) is set for the Aver-
age Movement Time of the SERVOPACK parameter.
Speed (V)
Time (t)
S-curve time constant (SCC)
When the acceleration/deceleration filter is disabled
Motion Module
SCC Command
Reference Range (ms)
Remarks
SVA-01
0 to 6553
−
SVB-01,
Built-in SVB
0 to 510
With the SGD-N, SGDB-N, SGDH+NS110/NS115, SGDS, SGDX, or
SGDV SERVOPACK
−
With the SGDJ SERVOPACK, the S-curve acceleration/deceleration can-
not be used since the SERVOPACK does not have a parameter for Aver-
age Movement Time.
PO-01
0 to 6553
−
SVR
0 to 6553
−
INFO