B.10 o: Operator-Related Settings

The o parameters set up the digital operator displays.

u

o1: Digital Operator Display Selection

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

o1-01

(0500) Drive Mode Unit

Monitor Selection

User Monitor Sel

Switches the display after the power has been turned on.

When using an LED operator, pressing the up arrow key will

display the following data: frequency reference → rotational

direction → output frequency → output current → output voltage

→ U1-oo.

Note:

Enter the “1-oo” portion of “U1-oo” to view

the monitor. Certain monitors are not available in

all control modes.

Default: 106

(Monitor

U1-06)

Range: 104 to

813

o1-02

(0501) User Monitor Selection

after Power Up

Power-On Monitor

1: Frequency Ref

2: FWD/REV

3: Output Freq

4: Output Current

5: User Monitor

Selects the information displayed on the digital operator when

the power is turned on.

1: Frequency reference (U1-01)

2: Direction

3: Output frequency (U1-02)

4: Output current (U1-03)

5: User-selected monitor (set by o1-01)

Default: 1

Range: 1 to 5

o1-03

(0502)

Digital Operator Display

Selection

Display Unit Sel

0: 0.01 Hz

1: 0.01 %

2: r/min

3: User Units

Sets the units the drive should use to display the frequency

reference and motor speed monitors.

0: 0.01 Hz

1: 0.01% (100% = E1-04)

2: r/min (calculated using the number of motor poles setting in

E2-04, E4-04, or E5-04)

3: User-selected units (set by o1-10 and o1-11)

Default:

<1>

Range: 0 to 3

o1-04

(0503) V/f Pattern Display Unit

V/f Ptrn Unit

0: Hertz

1: RPM

0: Hz

1: r/min

Default:

<1>

Range: 0, 1

o1-05

(0504)

<2>

LCD Contrast Control

LCD Contrast

Sets the contrast of the LCD operator.

Note:

This parameter is not available in models 4A0930

and 4A1200.

Default: 3

Min.: 0

Max.: 5

o1-10

(0520)

User-Set Display Units

Maximum Value

UserDisp Scaling

These settings define the display values when o1-03 is set to 3.

o1-10 sets the display value that is equal to the maximum output

frequency.

o1-11 sets the position of the decimal position.

Default:

<3>

Range: 1 to

60000

o1-11

(0521)

User-Set Display Units

Decimal Display

UserDisp Dec Sel

Default:

<3>

Range: 0 to 3

<1> Default setting is determined by parameter A1-02, Control Method Selection.
<2> Available in drive software versions PRG: 1019 and later.
<3> Default setting is determined by parameter o1-03, Digital Operator Display Selection.

u

o2: Digital Operator Keypad Functions

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

o2-01

(0505)

LO/RE Key Function

Selection

LO/RE Key

0: Disabled

1: Enabled

0: Disabled

1: Enabled. LO/RE key switches between LOCAL and REMOTE

operation.

Default: 1

Range: 0, 1

o2-02

(0506)

STOP Key Function

Selection

Oper STOP Key

0: Disabled

1: Enabled

0: Disabled. STOP key is disabled in REMOTE operation.

1: Enabled. STOP key is always enabled.

Default: 1

Range: 0, 1

o2-03

(0507)

User Parameter Default

Value

User Default Sel

0: No Change

1: Save User Init

2: Clear User Init

0: No change.

1: Set defaults. Saves parameter settings as default values for a

User Initialization.

2: Clear all. Clears the default settings that have been saved for

a User Initialization.

Default: 0

Range: 0 to 2

B.10 o: Operator-Related Settings

YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide

327

B

Parameter List