Yaskawa CIMR-AU 200V Drives User Manual
Page 325

No.
(Addr.
Hex)
Name
LCD Display
Description
Values
Page
n8-11
(054A)
<1>
Induction Voltage
Estimation Gain 2
InducedVEstGain2
Sets the gain for estimating the speed.
There is normally no need to change this parameter from the
default value.
Note:
This parameter is not available in models 4A0930
and 4A1200.
Default:
<2>
Min.: 0.0
Max.: 1000.0
–
n8-14
(054D)
<1>
Polarity Compensation
Gain 3
PoleComp Gain 3
Sets the gain for estimating the speed.
There is normally no need to change this parameter from the
default value.
Note:
This parameter is not available in models 4A0930
and 4A1200.
Default: 1.000
Min.: 0.000
Max.: 10.000
–
n8-15
(054E)
<1>
Polarity Compensation
Gain 4
PoleComp Gain 4
Sets the gain for estimating the speed.
There is normally no need to change this parameter from the
default value.
Note:
This parameter is not available in models 4A0930
and 4A1200.
Default: 0.500
Min.: 0.000
Max.: 10.000
–
n8-21
(0554)
<1>
Motor Ke Gain
Back EMF Gain
Sets the gain for estimating the speed.
There is normally no need to change this parameter from the
default value.
Note:
This parameter is not available in models 4A0930
and 4A1200.
Default: 0.90
Min.: 0.80
Max.: 1.00
–
n8-35
(562)
Initial Rotor Position
Detection Selection
Init Pole EstSel
0: Pull-In Method
1: Harm Inj Method
2: Pulse Method
0: Pull-in
1: High frequency injection
2: Pulse injection
Default: 1
Range: 0 to 2
–
n8-36
(0563)
<1>
High Frequency
Injection Level
PM Harm Inj Freq
Sets the frequency in Hz for the superimposed signal used for
superimposed harmonics. Enabled when n8-57 = 1.
There is normally no need to change this parameter from the
default value.
Note:
This parameter is not available in models 4A0930
and 4A1200.
Default: 500 Hz
Min.: 200
Max.: 1000
–
n8-37
(0564)
<1>
High Frequency
Injection Amplitude
PM Harm Inj Amp
Sets the amplitude for superimposed harmonics according to the
voltage class of the motor. Adjust this value when there is too
much or too little current as a result of the settings assigned to
motor parameters.
Enabled when n8-57 = 1.
There is normally no need to change this parameter from the
default value.
Note:
This parameter is not available in models 4A0930
and 4A1200.
Default: 20.0%
Min.: 0.0
Max.: 50.0
–
n8-39
(0566)
<1>
Low Pass Filter Cutoff
Frequency for High
Frequency Injection
PM Harm LPF Freq
Sets the cutoff frequency of a low pass filter for high frequency
injection. Enabled when n8-57 = 1.
There is normally no need to change this parameter from the
default value.
Note:
This parameter is not available in models 4A0930
and 4A1200.
Default: 50 Hz
Min.: 0
Max.: 1000
–
n8-45
(0538)
Speed Feedback
Detection Control Gain
(for PM Motors)
PM Spd Fdbk Gain
Increase this setting if hunting occurs. Decrease to lower the
response.
Default: 0.80
Min.: 0.00
Max.: 10.00
–
n8-47
(053A)
Pull-In Current
Compensation Time
Constant (for PM
Motors)
PM Pull-in I Tc
Sets the time constant to make the pull-in current reference and
actual current value agree. Decrease the value if the motor begins
to oscillate, and increase the value if it takes too long for the
current reference to equal the output current.
Default: 5.0 s
Min.: 0.0
Max.: 100.0
–
n8-48
(053B)
Pull-In Current (for PM
Motors)
PM No-load Curr
Defines the d-Axis current reference during no-load operation at
a constant speed. Set as a percentage of the motor rated current.
Increase this setting if hunting occurs while running at constant
speed.
Default: 30%
Min.: 20
Max.: 200
–
n8-49
(053C)
d-Axis Current for High
Efficiency Control (for
PM Motors)
EnergySav ID Lvl
Sets the d-Axis current reference when running a high load at
constant speed. Set as a percentage of the motor rated current.
Default:
<3>
Min.: -200.0%
Max.: 0.0%
–
n8-51
(053E)
Acceleration/
Deceleration Pull-In
Current (for PM Motors) PM Pull-in I@Acc
Sets the d-Axis current reference during acceleration/
deceleration as a percentage of the motor rated current. Set to a
high value when more starting torque is needed.
Default: 50%
Min.: 0
Max.: 200
–
B.9 n: Special Adjustment