Three-Phase 200 V Class Drive Models 2A0040 to 2A0211
Table A.3 Power Ratings Continued (Three-Phase 200 V Class)
Item
Specification
Drive Model
2A0040 2A0056 2A0069 2A0081 2A0110 2A0138 2A0169 2A0211
Maximum Applicable Motor Capacity
(HP)
<1>
ND Rating
15
20
25
30
40
50
60
75
HD Rating
10
15
20
25
30
40
50
60
Input
Input Current (A)
<2>
ND Rating
52
68
80
92
111
136
164
200
HD Rating
37
52
68
80
82
111
136
164
Rated Voltage
Rated Frequency
Three-phase 200 to 240 Vac 50/60 Hz/270 to 340 Vdc
<3>
Allowable Voltage Fluctuation
-15 to 10%
Allowable Frequency Fluctuation
±5%
Input Power (kVA)
ND Rating
24
31
37
42
51
62
75
91
HD Rating
17
24
31
37
37
51
62
75
Output
Rated Output Capacity
(kVA)
<4>
ND Rating
<5>
15.2
21
26
31
42
53
64
80
HD Rating
12.6
<6>
17.9
<6>
23
<6>
29
<6>
32
<6>
44
<6>
55
<7>
69
<7>
Rated Output Current (A)
ND Rating
<5>
40
56
69
81
110
138
169
211
HD Rating
33
<6>
47
<6>
60
<6>
75
<6>
85
<6>
115
<6>
145
<7>
180
<7>
Overload Tolerance
ND Rating: 120% of rated output current for 60 s
HD Rating: 150% of rated output current for 60 s
(Derating may be required for applications that start and stop frequently)
Carrier Frequency
User adjustable between 1 and 15 kHz
User adjustable
between 1 and
10 kHz
Maximum Output Voltage (V)
Three-phase 200 to 240 Vac (proportional to input voltage)
Maximum Output Frequency (Hz)
400 Hz (user-set)
<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than
the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.
<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring
connections, and power supply impedance.
<3> DC input is not available for UL standards.
<4> Rated motor capacity is calculated with a rated output voltage of 220 V.
<5> Carrier frequency is set to 2 kHz. Current derating is required in order to raise the carrier frequency.
<6> Carrier frequency can be increased to 8 kHz while keeping this current derating. Higher carrier frequency settings require derating.
<7> Carrier frequency can be increased to 5 kHz while keeping this current derating. Higher carrier frequency settings require derating.
A.2 Power Ratings
250
YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide