Yaskawa CIMR-AU 200V Drives User Manual
Page 243

• Use shielded wire for the PG encoder signal lines.
• Use separate conduit or cable tray dividers to separate option control wiring, main circuit input power wiring, and motor
output power cables.
PG-X3 Interface Circuit
26LS32 level
26LS31 level
PG X3
PG Encoder
A ,B ,Z
A+,B+,Z+
600
a ,b ,z
a+,b+,z+
SG
Monitor Signals
A,B,Z
A,B,Z 26LS31 level
Figure 7.12 PG-X3 Interface Circuit
PG-X3 Terminal Functions
Table 7.7 PG-X3 Option Terminal Functions
Terminal Block
Terminal
Function
Description
IG
IP
+
A
-
A
-Z
D
S
EF
Z+
+
B
-
B
TB1
TB2
SG
a+
a-
b+
b-
z+
z-
TB1
A+
A pulse signal input
• Inputs for the A channel, B channel, and Z
pulses from the PG encoder
• Signal level matches RS-422
A–
A inverse pulse signal input
B+
B pulse signal input
B–
B inverse pulse signal input
Z+
Z pulse signal input
Z–
Z inverse pulse signal input
SD
NC pin (open)
Open connection port for use when cable
shields should not be grounded
FE
Ground
Used as the shield ground termination point.
TB2
IP
PG encoder power supply
• Output voltage: 12.0 V ± 5% or 5.5 V ±
5%
• Max. output current: 200 mA
<1>
IG
PG encoder power supply common
SG
Monitor signal common
• Output signal for monitoring A channel, B
channel, and Z pulses from the PG encoder
• Signal level matches RS-422
a+
A pulse monitor signal
a–
A pulse inverse monitor signal
b+
B pulse monitor signal
b–
B pulse inverse monitor signal
z+
Z pulse monitor signal
z–
Z pulse inverse monitor signal
<1> A separate UL-listed class 2 power supply is necessary when the PG requires more than 200 mA to operate.
PG Encoder Power Supply Voltage
For the PG-X3 option, set the voltage for the PG encoder power supply using jumper CN3 located on the option. Position the
jumper as shown in
to select the voltage level.
NOTICE: The positioning of jumper CN3 selects the PG encoder power supply voltage (5.5 V or 12 V). Select the voltage level for the PG
encoder connected to the option and motor. If the wrong voltage is selected, the PG encoder may not operate properly or may become
damaged as a result.
Table 7.8 Setting the PG Encoder Power Supply Voltage (IP) with Jumper CN3
Voltage Level
5.5 V ± 5% (default)
12.0 V ± 5%
Jumper CN3
CN3
5.5 V 12 V
CN3
5.5 V 12 V
PG-X3 Wire Gauges and Tightening Torques
Wire gauge and torque specifications are listed in
. For simpler and more reliable wiring, use crimp ferrules on the
wire ends. Refer to the option manuals for the wire size and torque specifications of other options.
7.1 Option Card Installation
YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide
243
7
Peripheral Devices & Options